INPUT |
VOLTAGE(V) |
AC100~120V/200-240V (AC90~132V/180~264V
or DC255~370V), 50/60Hz (47~440Hz or DC) |
CURRENT(A) |
110V ~18.0A,220V ~9.0A |
FREQUENCY |
|
EFFICIENCY |
78 % typ |
INRUSH CURRENT |
30A typ(AC IN 110V, Io=100%),60A typ(AC
IN 220V, Io=100%)at cold start |
OUTPUT |
VOLTAGE(V) |
5 |
CURRENT(A) |
170 |
REGULATION,LINE(mV) |
25 Max |
REGULATION,LOAD(mV) |
50 Max |
RIPPLE(mVP-P) |
50 Max |
RIPPLE,NOISE(mVP-P) |
100 Max |
TEMPRETURE DRIFT,0~+50℃(mV) |
75 Max |
RISE TIME(mS) |
800 Max(AC IN 110V/220V Io=100%) |
HOLDING TIME(mS) |
17 typ (AC IN 110V/220V Io=100%) |
PROTECTION CIRCUIT |
OVERCURRENT PROTECTION |
Works at over 110% of rating and recovers
automatically |
OVERVOLTAGE PROTECTION |
Works at 115~140% of rating(In the case
of 3.3V,it is 115~160%) |
ELECTRICALLY ISOLATED |
INPUT-OUTPUT |
AC1,500V 1 minute current 20mA, DC 500V
100MΩ(At room temperature & Humidity) |
INPUT-CASE,FG |
AC1,500V 1 minute current 20mA, DC 500V
100MΩ(At room temperature & Humidity) |
OUTPUT-CASE,CASE |
AC 500V 1 minute current 100mA, DC 500V
100MΩ(At room temperature & Humidity) |
ENVIRONMENT |
OPERATING TEMP.AND HUMID. |
-10~+50℃, 20~90% RH(Non condensing) |
STORAGE TEMP.AND HUMID. |
-20~+75℃, 20~90% RH(Non condensing) |
VIBRATION |
10~55Hz at 1G, 3 minutes period, 30 minutes
along X,Y and Z axis |
IMPACT |
10G for 20ms once on each X,Y and Z axis |
SAFETY |
SAFETY REGULATION |
|
LINE CONDUCTED RF VOLTAGE |
|