INPUT |
VOLTAGE(V) |
AC100-120V (AC85~132V or
DC120~186V), 50/60Hz (44~440Hz or DC) |
CURRENT(A) |
100V ~3.2A |
FREQUENCY |
|
EFFICIENCY |
80 % typ |
INRUSH CURRENT |
20A typ(AC IN 110V, Io=100%) |
OUTPUT |
VOLTAGE(V) |
15 |
CURRENT(A) |
10.0 |
REGULATION,LINE(mV) |
75 Max |
REGULATION,LOAD(mV) |
150 Max |
RIPPLE(mVP-P) |
150 Max |
RIPPLE,NOISE(mVP-P) |
200 Max |
TEMPRETURE DRIFT,0~+50℃(mV) |
225 Max |
RISE TIME(mS) |
1,000 Max(AC IN 110V Io=100%) |
HOLDING TIME(mS) |
17 typ (AC IN 110V Io=100%) |
PROTECTION CIRCUIT |
OVERCURRENT PROTECTION |
Works at over 110% of rating and recovers
automatically |
OVERVOLTAGE PROTECTION |
Works at 115~140% of rating(by zener
diode clamp).In the case of 3.3V,it is 115~160% |
ELECTRICALLY ISOLATED |
INPUT-OUTPUT |
AC 3,000V 1 minute current 20mA, DC 500V
100MΩ(At room temperature & Humidity) |
INPUT-CASE,FG |
AC 2,000V 1 minute current 20mA, DC 500V
100MΩ(At room temperature & Humidity) |
OUTPUT-CASE,CASE |
AC 500V 1 minute current 100mA, DC 500V
100MΩ(At room temperature & Humidity) |
ENVIRONMENT |
OPERATING TEMP.AND HUMID. |
-10~+50℃, 20~90% RH(Non condensing) |
STORAGE TEMP.AND HUMID. |
-20~+75℃, 20~90% RH(Non condensing) |
VIBRATION |
10~55Hz at 1G, 3 minutes period, 30 minutes
along X,Y and Z axis |
IMPACT |
10G for 20ms once on each X,Y and Z axis |
SAFETY |
SAFETY REGULATION |
|
LINE CONDUCTED RF VOLTAGE |
|