AC-DC>MSF Series>MSF300-12
 
SPECIFICATIONS
   
INPUT VOLTAGE(V) AC100~120V/200-240V (AC90~132V/180~264V or DC255~370V), 50/60Hz (47~440Hz or DC)
CURRENT(A) 100V ~7.0A,200V ~3.5A
FREQUENCY  
EFFICIENCY 78 % typ
INRUSH CURRENT 30A typ(AC IN 110V, Io=100%),60A typ(AC IN 220V, Io=100%) at cold start
OUTPUT VOLTAGE(V) 12
CURRENT(A) 25.0
REGULATION,LINE(mV) 60 Max
REGULATION,LOAD(mV) 120 Max
RIPPLE(mVP-P) 120 Max
RIPPLE,NOISE(mVP-P) 170 Max
TEMPRETURE DRIFT,0~+50℃(mV) 180 Max
RISE TIME(mS) 500 Max(AC IN 110V, Io=100%)
HOLDING TIME(mS) 16 typ (AC IN 110V, Io=100%)
PROTECTION CIRCUIT OVERCURRENT PROTECTION Works at over 110% of rating and recovers automatically
OVERVOLTAGE PROTECTION Works at 115~140% of rating(In the case of 3.3V,it is 115~160%)
ELECTRICALLY ISOLATED INPUT-OUTPUT AC 3,000V 1 minute current 20mA, DC 500V 100MΩ(At room temperature & Humidity)
INPUT-CASE,FG AC 2,000V 1 minute current 20mA, DC 500V 100MΩ(At room temperature & Humidity)
OUTPUT-CASE,CASE AC 500V 1 minute current 100mA, DC 500V 100MΩ(At room temperature & Humidity)
ENVIRONMENT OPERATING TEMP.AND HUMID. -10~+50℃, 20~90% RH(Non condensing)
STORAGE TEMP.AND HUMID. -20~+75℃, 20~90% RH(Non condensing)
VIBRATION 10~55Hz at 1G, 3 minutes period, 30 minutes along X,Y and Z axis
IMPACT 10G for 20ms once on each X,Y and Z axis
SAFETY SAFETY REGULATION UL,C-UL,CE
LINE CONDUCTED RF VOLTAGE Complied with FCC Part15 and EN55022 Class A Limits
DIMENSION FIGURE